#6292 closed defect (fixed)

PDF: Incorrect georeferencing with OGC Best Practice encoding and non-meter units (and particularly US Foot)

Reported by: Even Rouault Owned by: Even Rouault
Priority: normal Milestone:
Component: default Version: unspecified
Severity: normal Keywords: pdf ogc bp foot
Cc:

Description (last modified by Even Rouault)

Demonstrated by https://drive.google.com/file/d/0B4shTM1bPS5TMDhNMUpkUC04RlE/view?usp=sharing

The OGC BP spec is not clear at all, but it seems that when a non-meter linear units is specified, it applies only to the SRS linear parameters, but not to the geotransform itself.

Change History (2)

comment:1 by Even Rouault, 8 years ago

Keywords: ogc bp foot added
Resolution: fixed
Status: newclosed

trunk r32772, branches/2.0 r32773, branches/1.11 r32774 "PDF: correctly take into account non-meter linear units with OGC BP encoding, and add support for US FOOT (#6292)"

comment:2 by Even Rouault, 8 years ago

Description: modified (diff)