Version 5 (modified by 14 years ago) ( diff ) | ,
---|
FDO RFC 55 - Convert FdoDecimal(p,0) datatype to FdoInt32 for SHP Provider
This page contains an change request (RFC) for the FDO Open Source project. More FDO RFCs can be found on the RFCs page.
Status
RFC Template Version | (1.0) |
Submission Date | January 14, 2011 |
Last Modified | Dan Stoica January 14, 2011 |
Author | Dan Stoica |
RFC Status | Draft |
Implementation Status | final |
Proposed Milestone | 3.5.0.0 |
Assigned PSC guide(s) | Greg Boone |
Voting History | |
+1 | Haris, Jackie, Greg, Orest, Jason |
+0 | |
-0 | |
-1 |
Overview
This RFC is for handling the cases where DBF files contain DECIMAL(precision, 0) columns.
Motivation
The motivation is well explained by: Ticket #365 [SHP Provider]: When executing IApplySchema, Int32 properties are converted to Decimal properties http://trac.osgeo.org/fdo/ticket/365
If you execute an IApplySchema on a SHP connection. Any Int32 properties in any class definitions inside the schema (to be applied) will be converted to Decimal properties once the schema has been applied. This does not happen if the Int32 property happens to be an Identity property. <<
For further clarification "will be converted to Decimal properties" refer to FdoDecimal properties.
Note storing FdoInt32 as Decimals is expected since by specification DBF files natively do not have an integer type, but only DECIMAL(precision, scale) datatype. The same apply to double and single precision datatypes. Hence a FdoInt32 is mapped to a DECIMAL(11, 0) column type.
The impact is on Describe Schema when currently a FdoDecimal is returned for a DECIMAL column even in the cases when the scale is zero and most probably the original type was a FdoInt32.
This RFC is required since reading back a FdoInt32 instead of a FdoDecimal is a change in behavior.
Proposed Solution
Modify the FDO SHP provider:
- the DBF to FDO datatype mapping (physical to logical conversion) needs a small refinement. In the case of DECIMAL(precision, scale) check the scale value. When the scale is 0 (zero) then return an FdoInt32 rather than an FdoDecimal. Note SHP doesn't support FdoInt64 or FdoInt16 datatypes therefore the mapping to FdoInt32 is unique.
Implications
- In the case of physical DECIMAL(precision, scale) column the corresponding logical FDO property type will be set according to the scale. The caller must expect either a FdoDecimal or a FdoInt32 when reading a SHP schema.
- This is a behavior change for the SHP provider. Before this change, SHP would return only FdoDecimal for all numerical FDO types. It would never return an Int32 except for the identity property (which actually is not stored).
- The provider will return a FdoInt32 even for properties which originally were DECIMAL(p, 0). This issue can be mitigated by noting the SHP provider already does silent corrections on the fly in certain cases, like truncating the property names when found too long (both on reading and writing).
Test Plan
- Enhance the unit test and add roundtripping fidelity tests for FdoInt32 properties.
Funding/Resources
Autodesk to provide resources/funding.