    3333'''Issues with CF-1 implementation of specific projections''':
    3434
    35  * AEA : The OGC WKT version has 2 Std parallels - whereas the CF-1.5 version says it can have either 1 or 2 std parallels. How should the CF 1SP version be converted to OGC WKT, and vice-versa? Currently the driver imports an AEA with 2 identical std_parallels.
     35 * AEA : The OGC WKT version has 2 Std parallels - whereas the CF-1.5 version says it can have either 1 or 2 std parallels. How should the CF 1SP version be converted to OGC WKT, and vice-versa?
     36  * Currently the driver, on import and finding an AEA with only 1 std parallel, will set the 2nd std parallel in the WKT as identical to the first.
    3637 * LCC : The OGC WKT 'Lambert_Conformal_Conic_2SP' maps clearly to LCC in CF-1 with 2 std parallels. The CF-1 spec claims that a 1SP version can be used, but it doesn't include a 'scale_factor' as does the OGC WKT 'Lambert_Conformal_Conic_1SP'. Is mapping std_parallel_1 maps to latitude_of_origin and setting scale_factor=1 correct? (see bug #3324)
    3738 * CEA : The CF-1 conventions claim this can be encoded with a 'scale_factor_at_projection_origin' alternative to standard parallel - how would this conversion be done back from OGC WKT?