Opened 13 years ago

Last modified 13 years ago

#3881 closed enhancement

S57 driver: add support for Dutch inland ENCs — at Initial Version

Reported by: hogendrr Owned by: warmerdam
Priority: normal Milestone: 1.9.0
Component: OGR_SF Version: 1.7.3
Severity: normal Keywords: S57
Cc:

Description

Dutch inland ENCs are encoded in a slightly different way than most (maritime) ENCs. They are, however, compliant with the IHO S57 3.1 specification. The difference is that in a vector record (section 7.7 of the S57 spec), a line can be encoded in two ways: one SG2D record with repeating rows or a repeating series of SG2D with one row (or even a combination thereof).
The current (1.7.3) driver only supports the former encoding. This patch adds support for the both encodings.
Tested against inland ENCs at ftp://sdg.ivs90.nl/ENC/ and several maritime ENCs

Change History (1)

Note: See TracTickets for help on using tickets.